
The count rate of a Geiger- Muller counter for the radiation of a radioactive material of half-life of 30 minutes decreases to $5s^{-1}$ after 2 hours. The initial count rate was
A. $25 s^{-1}$
B. $20 s^{-1}$
C. $80 s^{-1}$
D. $625 s^{-1}$
Answer
179.7k+ views
Hint: The Geiger-Muller counter is used for measuring the radiation emitted by a radioactive material. Half-life of the material is also given. After 2 hrs it rate decreases to $5s^{-1}$. We have to find the initial rate using the given data.
Formula used:
We can use the same formula connecting amount of the original sample, remaining amount of the sample, half-life and time taken for decay:
$\dfrac{N}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{t}{T}}$
Where $\mathrm{N}$ is the amount of sample remaining after $t$ time or final rate.
$N_{0}$ is the original amount of sample or initial rate.
$\mathrm{T}$ is the half-life of the radioactive material.
Complete answer:
We have a radioactive material of half-life 30 minutes. And the count rate of Gieger-Muller counter
decreases to $5 s^{-1}$ after 2 hrs. With these data we have to find the initial rate shown in
Geiger-Muller counter.
In order to find the initial rate, we have the equation connecting all the known factors in question as:
$\dfrac{N}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{t}{T}}$
Here we have to find $N_{0}$ that is the initial count rate.
Final count rate, $N=5 s^{-1}$
Half-life of the radioactive material, $T=30$ minutes
Time taken, $t=2 h r s=120$ minutes
On substituting the values in the equation, we get:
$\dfrac{5}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{120}{30}}$
Therefore, initial count rate is:
$N_{0}=\dfrac{5}{\left(\dfrac{1}{2}\right)^{4}}=5 \times 2^{4}=16 \times 5=80 s^{-1}$
Thus, option (D) is correct.
Additional information: The Geiger-Muller counter is an instrument which measures and detects ionization produced by radiation. It can count particles at rates up to 10,000 per second. Radioactive particles produce radiation when it decays. So, it can also be used to measure decay of radioactive materials.
Note: Amount here is taken as the rate since the rate is given in the question. Radioactivity measurement means how much of radioactivity has decayed. So, we can replace the amount with the rate. Don’t forget to convert the unit of time before calculating.
Formula used:
We can use the same formula connecting amount of the original sample, remaining amount of the sample, half-life and time taken for decay:
$\dfrac{N}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{t}{T}}$
Where $\mathrm{N}$ is the amount of sample remaining after $t$ time or final rate.
$N_{0}$ is the original amount of sample or initial rate.
$\mathrm{T}$ is the half-life of the radioactive material.
Complete answer:
We have a radioactive material of half-life 30 minutes. And the count rate of Gieger-Muller counter
decreases to $5 s^{-1}$ after 2 hrs. With these data we have to find the initial rate shown in
Geiger-Muller counter.
In order to find the initial rate, we have the equation connecting all the known factors in question as:
$\dfrac{N}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{t}{T}}$
Here we have to find $N_{0}$ that is the initial count rate.
Final count rate, $N=5 s^{-1}$
Half-life of the radioactive material, $T=30$ minutes
Time taken, $t=2 h r s=120$ minutes
On substituting the values in the equation, we get:
$\dfrac{5}{N_{0}}=\left(\dfrac{1}{2}\right)^{\dfrac{120}{30}}$
Therefore, initial count rate is:
$N_{0}=\dfrac{5}{\left(\dfrac{1}{2}\right)^{4}}=5 \times 2^{4}=16 \times 5=80 s^{-1}$
Thus, option (D) is correct.
Additional information: The Geiger-Muller counter is an instrument which measures and detects ionization produced by radiation. It can count particles at rates up to 10,000 per second. Radioactive particles produce radiation when it decays. So, it can also be used to measure decay of radioactive materials.
Note: Amount here is taken as the rate since the rate is given in the question. Radioactivity measurement means how much of radioactivity has decayed. So, we can replace the amount with the rate. Don’t forget to convert the unit of time before calculating.
Recently Updated Pages
Degree of Dissociation Important Concepts and Tips for JEE

JEE Main Chemistry Question Paper PDF Download with Answer Key

JEE Electricity and Magnetism Important Concepts and Tips for Exam Preparation

JEE Energetics Important Concepts and Tips for Exam Preparation

JEE Isolation, Preparation and Properties of Non-metals Important Concepts and Tips for Exam Preparation

States of Matter Chapter For JEE Main Chemistry

Trending doubts
JEE Main 2025 Session 2: Application Form (Out), Exam Dates (Released), Eligibility, & More

JEE Main 2025: Derivation of Equation of Trajectory in Physics

Displacement-Time Graph and Velocity-Time Graph for JEE

Electric field due to uniformly charged sphere class 12 physics JEE_Main

Atomic Structure - Electrons, Protons, Neutrons and Atomic Models

Learn About Angle Of Deviation In Prism: JEE Main Physics 2025

Other Pages
JEE Advanced Marks vs Ranks 2025: Understanding Category-wise Qualifying Marks and Previous Year Cut-offs

What is Hybridisation in Chemistry?

JEE Main 2025: Conversion of Galvanometer Into Ammeter And Voltmeter in Physics

JEE Advanced Weightage 2025 Chapter-Wise for Physics, Maths and Chemistry

Wheatstone Bridge for JEE Main Physics 2025

Electric Field Due to Uniformly Charged Ring for JEE Main 2025 - Formula and Derivation
